Our experience in the fluids industry has made INDUSTRIAL PUMPING the preferred supplier of pumps, filtration and fluid control equipment, to many world respected mines, councils, oil palm mills, sugar mills, public utilities, and factories, in Australia, Papua New Guinea, and South Pacific Islands.


Click here to return to Index page
ULTRA VIOLET STERILISER PRODUCT INFORMATION


Australian Ultra-Violet Products

THE LEADERS IN WATER STERILISATION


Ultraviolet disinfection is a non-chemical approach to disinfection. In this method of disinfection, no chemicals are added, which makes this process simple, inexpensive and requires very low maintenance. Ultraviolet sterilisers utilize germicidal lamps that are designed to produce a certain dosage of ultraviolet, at least 16,000 micro watt seconds per square centimetre. The principle of design is based on a product of contact time and intensity.


Sunlight naturally contains Ultra-Violet wavelengths which disinfects water. The Ultra-Violet wavelengths 200 to 290 nanometres (nm) penetrate cell membranes to disrupt the DNA molecules preventing cell replication with a maximum effectiveness around 260 nm, depending on the organism. The Ultra-Violet light generated by the Australian Ultra-Violet mercury vapour lamp is particularly rich in these microbicidal wavelengths to ensure maximum disinfection efficiency.

WATER DISINFECTION Australian Ultra-Violet Products produce a wide range of Ultra-Violet disinfection units which can be used from domestic applications, through Industrial to Municipal disinfection units.

Unlike chlorination, there are no micro-organisms known to be immune to Ultra-Violet light which is highly effective against bacteria, viruses, algae, moulds and yeasts. In practice bacteria and viruses are the cause of the major waterborne pathogenic diseases. Of these, enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by Ultra-Violet treatment. Also of concern is the fact that chlorine forms trihalomethanes in drinking water whereas Ultra-Violet treatment does not produce any toxic by-products.


ORGANISM DISEASE and percentage reduction of waterborne organisms pathogenic to man.

Bacteria
Salmonella typhi Typhoid Fever 99.999%
Salmonella enteritidis Gastroenteritis 99.999%
Shigella disenteriae Dysentery 99.999%
Vibrio cholerae Cholera 99.999%
Enteropathogenic Escherichia Coli Gastroenteritis 99.999%
Leptospira icterohaemorrhagiae Weil's disease 99.999%
Mycobacterium tuberculosis Tuberculosis 99.999%
Legionella pneumophila Legionnaires' Disease 99.999%

Viruses
Hepatitis A virus Infectious hepatitis 90%
Polio virus Poliomyelitis 99.999%
Enteroviruses Gastroenteritus 99%



UViFLO LCS-1 & 2

Electro polished 316L stainless steel.


Peak flow rate for clean water:

1,000 lph for the LCS-1 unit
2,000 lph for the LCS-2 unit

Chamber Dimensions
- LCS-1 420mm x 62mm
- LCS-2 505mm x 62mm

Inlet / Outlet Ports:
- 3/4" male BSP opposite sides.

Lamps:
All lamps are rated for a 9,000 hour life.

All sterilisers are supplied with power boxes suited to 240 VAC, 50Hz power supplies. (12 volt DC available on LCS-1)



UViFLO LCS-4, 7, 10 & 17

Electro polished 316L stainless steel.


Peak flow rate for clean water:

4,000 lph for the LCS-4 unit
7,000 lph for the LCS-7 unit
10,000 lph for the LCS-10 unit
17,000 lph for the LCS-17 unit

Chamber Dimensions:
- LCS-4/7 895mm x 76mm
- LCS-10/17 1210mm x 76mm

Inlet / Outlet Ports:
- LCS-4 = 1 1/2" male BSP opposite sides.
- LCS-7/10/17 = 2" male BSP opposite sides.

UV Lamps:
All lamps are rated for a 12,000 hour life.

All sterilisers are supplied with power boxes suited to 240 VAC, 50Hz power supplies.







UViFLO LCP-4 & LCP-8

uPVC Reactor Body.


Peak flow rate for clean water:

4,000 lph for the LCP-4 unit
8,000 lph for the LCP-8 unit

Chamber Dimensions:
- LCP-4/8 = 900mm x 110mm

Inlet / Outlet Ports:
- all units have 2" uPVC slip sockets on opposite sides of the chamber.

UV Lamps:
All lamps are rated for a 12,000 hour life.

All sterilisers are supplied with power boxes suited to 240 VAC, 50Hz power supplies.







UViFLO LCP-15 & LCP 20

Polythene Reactor Body.


Peak flow rate for clean water:

15,000 lph for the LCP-15 unit
20,000 lph for the LCP-20 unit

Chamber Dimensions:
- LCP-15/20 1210mm x 110mm

Inlet / Outlet Ports:
- all units have 2" uPVC Solvent Weld Unions on opposite sides of the chamber.

UV Lamps:
All lamps are rated for a 12,000 hour life.

All sterilisers are supplied with fan cooled power boxes suited to 240 VAC, 50Hz power supplies.







UViTANK 40

For the sterilisation of the air space inside tanks

Material; Stainless Steel, grade 316
Insert Length = 840mm
Tank Connection; 2" female BSPM
One 40 watt UV lamp
UV Rated Lamp Life; 6500 hours (9 months)
Weight of Tank Unit 1kg
Radius of area treated 2 metres
Standard PVC Power Supply Box:
Voltage 240 VAC, 50Hz




Click here to return to Index page



© 2009 Industrial Pumping Pty Ltd, 76 Scott Street, Cairns, Qld. Australia - Ph: 61-740312755 - Fax: 61-740314416 - All rights reserved - Bookmark and Share
contact us by email return to front page